Location:HOME > News > detail

Detail 5 characteristics of ethylene oxide sterilizer

font size:littlemiddleBig

Ethylene oxide sterilization gas is one of the most commonly used sterilization methods for low temperature sterilization. Ethylene oxide sterilization is widely used in the field of sterilization of medical device products. Due to the active type of ethylene oxide gas, strong sterilization power, wide sterilization spectrum, and slight damage to articles, the mixed gas of ethylene oxide and carbon dioxide has become one of the most important daily low-temperature sterilization methods.
The main features of Shuoshi ethylene oxide sterilizer are as follows:
1. International safety certification: The ethylene oxide sterilizer has an excellent user safety record in the sales process in recent years.
2. Single-dose sterilization gas tank: an individually packaged small-dose ethylene oxide gas tank, used with 5XL and 8XL, without additional connecting wires and filters, which can directly and safely release ethylene oxide gas into the sterilizer chamber. Before the sterilization process is actually started, 3 can self-check the sterilization conditions at that time. When the conditions are met, the sterilizer will automatically pierce the gas tank and release the sterilant. At the end of the sterilization process, the air tank and other sterilized items can be disposed of as ordinary medical waste after ventilation, which is convenient and safe.
3. Strong penetration performance: The penetration performance of the sterilant is very important for the sterilization process, especially for medical devices with complex structures. The boiling point of ethylene oxide is 10.7°C, and the vapor pressure is 1094 mmHg/20°C. These physical properties make ethylene oxide have very good penetration ability, can effectively contact every surface of the item to be sterilized, and then inactivate microorganisms.
4. Excellent stability: ethylene oxide gas molecules have good stability in the sterilization process. This ensures that the ethylene oxide gas will not decompose or degrade itself when penetrating the items to be sterilized, and can effectively ensure the effective gas concentration of each surface to be sterilized, thereby ensuring the quality of sterilization.
5. Perfect quality control: Ethylene oxide has been widely used in medical institutions for nearly 50 years. In this process, a lot of technical experience has been accumulated, and there are many innovations in quality monitoring and control. There is a mature and recognized sterilization quality monitoring system in the world.

Updated:2021-02-25